Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K210205

    Validate with FDA (Live)

    Date Cleared
    2021-03-26

    (59 days)

    Product Code
    Regulation Number
    888.3030
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    DePuy Synthes 3.5 mm/4.5 mm VA-LCP PPFx Proximal Femur Plates and Proximal Femur Hook Plates are indicated for the treatment of periprosthetic fractures in the presence of intramedullary implants in the proximal end segment and the proximal and middle 1/3 of the diaphyseal segment of the femur, and non-unions of such fractures, in adult patients, particularly in osteoporotic and osteopenic bone.

    DePuy Synthes 3.5 mm VA Locking Attachment Plate is indicated to augment the stabilization of fractures, including periprosthetic fractures (Vancouver Type B when used with either the 3.5 mm VA-LCP PPFx Proximal Femur Plate or Proximal Femur Hook Plate; Vancouver Type B and C when used with other DePuy Synthes LCP plates and VA-LCP plates) and fractures in the presence of intramedullary implants, in the femur, tibia, and humerus.

    DePuy Synthes 3.5 mm VA Locking PPFx Distal Femur Spanning Attachment Plates (when used with either 3.5 mm/4.5 mm VA-LCP PPFx Proximal Femur Plate or the Proximal Femur Hook Plate) can be used to extend the length of a plate construct to the lateral condyles.

    DePuy Synthes 3.5 mm VA Locking PPFX Greater Trochanter Ring Attachment Plates (when used with 3.5 mm/4.5 mm VA-LCP PPFx Proximal Femur Plate) are indicated for fixation or re-attachment of the greater trochanter following fracture or osteotomy.

    DePuy Synthes 3.5 mm VA Locking PPFX Greater Trochanter Hook Plates are indicated for fixation or re-attachment of the greater trochanter following fracture or osteotomy.

    Device Description

    The DePuy Synthes 3.5/4.5 mm Variable Angle LCP Periprosthetic Proximal Femur Plating System of Stainless Steel Plates for periprosthetic fractures. It consists of plates that offer screw to plate non-locking constructs, locking constructs or a combination of both. The plates accept commercially available DePuy Synthes Stainless Steel 3.5 mm cortex screws, 3.5 mm (variable angle) locking screws, 4.5 mm cortex screws and 5.0 mm (variable angle) locking screws, as well as the Synthes Orthopaedic Cable system.

    The DePuy Synthes 3.5/4.5 mm Variable Angle LCP Periprosthetic Proximal Femur Plating System offers:
    • 3.5 mm/4.5 mm VA-LCP PPFx Proximal Femur Plates
    • 3.5 mm/4.5 mm VA-LCP PPFx Proximal Femur Hook Plates
    • 3.5 mm VA Locking PPFx Distal Femur Spanning Attachment Plate
    • 3.5 mm VA Locking PPFx Greater Trochanter Hook Plate
    • 3.5 mm VA Locking PPFx Greater Trochanter Ring Attachment Plate
    • 3.5 mm VA Locking Attachment Plate

    AI/ML Overview

    This document is a 510(k) Premarket Notification from the FDA for a medical device. It describes the device, its intended use, and its comparison to predicate devices, along with non-clinical performance data. However, it does NOT describe an AI/ML powered device, nor does it contain any information about a study proving device meets acceptance criteria related to AI/ML performance, such as human reader improvement with AI assistance, standalone algorithm performance, or the establishment of ground truth by multiple experts.

    Therefore, I cannot provide the requested information. The document focuses on the substantial equivalence of a physical orthopedic implant system to existing predicate devices, based on mechanical, MRI compatibility, sterilization, shelf-life, and biological safety testing. It does not mention any AI or machine learning components.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1